HvacGauge: HVAC Charge & P-T Android app icon
Field Trades & Contractorscom.hvacgauge.ptpro

HvacGauge: HVAC Charge & P-T

Offline A2L P-T charts, superheat & subcooling diagnostics, and one-page commissioning PDFs for HVAC techs.

HvacGauge puts a dual-gauge digital manifold calculator, A2L refrigerant P-T tables, rule-based fault diagnostics, and on-site commissioning certificates into an offline Android toolkit built for mechanical rooms, rooftops, and crawlspaces.

100% OfflineA2L & A3 ReadyCommissioning PDFNo Account Needed

App Interface & Screenshots

Actual Google Play Store screens from HvacGauge.

HvacGauge: HVAC Charge & P-T screenshot 1 showing offline HVAC P-T chart superheat calculator
HvacGauge: HVAC Charge & P-T screenshot 2 showing offline HVAC P-T chart superheat calculator
HvacGauge: HVAC Charge & P-T screenshot 3 showing offline HVAC P-T chart superheat calculator
HvacGauge: HVAC Charge & P-T screenshot 4 showing offline HVAC P-T chart superheat calculator
HvacGauge: HVAC Charge & P-T screenshot 5 showing offline HVAC P-T chart superheat calculator
HvacGauge: HVAC Charge & P-T screenshot 6 showing offline HVAC P-T chart superheat calculator
The Problem

Why Standard Tools Fail in Real Conditions

Transitioning from R-410A to A2L refrigerants like R-454B and R-32 makes outdated laminated P-T sliders risky and slow—especially when zeotropic blends require separate dew and bubble curves to compute superheat versus subcooling accurately. Standing in a concrete basement or on a blazing-hot commercial roof with one bar of signal, waiting on a cloud FSM app to load just to log pressures or hand a homeowner proof of commissioning wastes billable truck time. Even worse, raw suction and liquid pressures rarely tell the full story by themselves. Technicians still have to mentally cross-check target superheat, airside temperature split, run-capacitor microfarad drift, and line-set weigh-in adjustments—then copy all those numbers onto a clipboard before invoicing the visit.

The Solution

How HvacGauge Solves It Offline

HvacGauge unifies dual-side P-T lookups for 8 core refrigerants with live superheat, subcooling, airflow fault diagnostics, run-capacitor pass/fail grading, and line-set charge math. Store equipment model, serial number, rated microfarads, and target subcooling per client unit, price the visit on site, and text or email a one-page Commissioning & Diagnostic Certificate PDF before leaving the driveway.

Key Features of HvacGauge

Engineered for speed, accuracy, and privacy with zero mandatory cloud dependencies.

Dual-Gauge P-T Data for 8 Refrigerants

A2L Ready

Read low-side and high-side saturation temperatures for R-410A, R-454B, R-32, R-22, R-134a, R-404A, R-407C, and R-290, complete with dedicated dew and bubble curves for zeotropic blends like R-454B and R-407C.

Live Superheat, Subcooling & Airside Delta-T

Diagnostics

Enter suction and liquid line temperatures alongside manifold pressures to calculate actual superheat, subcooling, target superheat, and airside temperature split, backed by an always-visible A2L and A3 safety banner.

Rule-Based Charge & Airflow Fault Matrix

Fault Matrix

Go beyond pressure readouts with a plain-language diagnostic matrix that flags undercharge, overcharge, restriction, and airflow anomalies so techs can confirm root cause before adding refrigerant.

Run-Capacitor Microfarad Test & Line-Set Weigh-In

Field Math

Evaluate measured capacitor microfarads against stored unit ratings with clear PASS, MARGINAL, and FAILED bands, and compute factory line-set charge trim in ounces per foot.

One-Page Commissioning & Diagnostic Certificate PDF

Client PDF

Combine refrigerant, capacitor, and service-call line-item pricing with measured system performance in a clean one-page PDF certificate ready to send by SMS or email right from the driveway.

Client Equipment History with Daylight & Attic Themes

100% Offline

Save each client unit's address, equipment make, model, serial number, target subcooling, and rated microfarads locally on device, with high-contrast light and dark themes for sun glare or dark attics.

Built for Real-World Workflows

How professionals and everyday users put HvacGauge to work.

Residential HVAC Service Technicians

Commissioning a new R-454B split heat pump in a new-build subdivision with zero cellular service and verifying subcooling against the condenser nameplate.

Outcome: Uses the R-454B bubble curve for accurate subcooling, calculates extra line-set charge in oz/ft, and texts a stamped one-page commissioning PDF to the builder before pulling away.
Commercial Refrigeration & Rooftop Techs

Troubleshooting a low-suction walk-in cooler running R-404A or R-407C while balancing evaporator airflow and checking compressor start/run components.

Outcome: Checks dew vs. bubble saturation temperatures offline, validates the run capacitor in seconds, and logs the fault matrix findings under the unit's serial number for the next PM visit.
Independent Owner-Operators

Running solo summer no-cool calls where transparent documentation prevents callbacks and justifies refrigerant and capacitor replacements on the spot.

Outcome: Prices refrigerant, capacitor, and service-call charges per client inside HvacGauge and emails an itemized diagnostic certificate that builds immediate homeowner trust.

HvacGauge vs. Paper P-T Charts & Cloud Field Apps

Side-by-side comparison across offline reliability, privacy, and workflow speed.

CapabilityHvacGaugePaper Charts / Cloud FSM
A2L & Zeotropic Glide HandlingBuilt-in dew & bubble curves for R-454B, R-407C, plus R-32 & R-290 safety bannersManual slider interpolation prone to dew/bubble mix-ups
Zero-Signal Mechanical Rooms100% offline local engine with instant launch and zero server waitCloud FSM logins stall or lose unsaved service forms offline
Fault InterpretationRule-based charge & airflow fault matrix plus capacitor PASS/MARGINAL/FAILED bandsRaw pressure numbers with no structured diagnostic summary
Commissioning & Warranty ProofOne-page Commissioning & Diagnostic Certificate PDF sent by SMS or emailHandwritten clipboard notes or back-office admin typing later
Cost & Account FrictionFree tier (3 units, 1 PDF, all P-T tools); no forced account creationExpensive monthly per-seat SaaS subscriptions and mandatory logins

How to Get Started in 3 Steps

STEP 01

Select Refrigerant & Enter Readings

Pick from 8 built-in refrigerants including R-454B, R-32, R-410A, and R-290, then input low-side and high-side pressures, line temperatures, and airside readings.

STEP 02

Verify Diagnostics & Component Health

Review live superheat, subcooling, dew/bubble saturation values, the charge and airflow fault matrix, capacitor microfarad status, and line-set weigh-in math.

STEP 03

Price the Call & Share the PDF Certificate

Save readings to the client unit's model/serial history, apply refrigerant and capacitor pricing, and export a one-page Commissioning & Diagnostic Certificate PDF on site.

Technical Specifications & Privacy Facts

Platform
Android (Google Play)
Offline Capability
100% offline — all P-T tables, diagnostics, and unit records run locally
Account Requirement
None — zero sign-up or cloud login required
Privacy Model
Local-only storage; diagnostic logs stay on your phone unless shared
Output / Format
One-page Commissioning & Diagnostic Certificate PDF (SMS/email)
Pricing
Free (3 client units, 1 PDF, all P-T tools); HvacGauge Pro for unlimited units & PDFs

HvacGauge FAQ

Common questions about offline HVAC P-T chart superheat calculator, offline support, and privacy.

Which refrigerants and A2L blends are included in HvacGauge?
HvacGauge includes offline low-side and high-side P-T data for 8 refrigerants: R-410A, R-454B, R-32, R-22, R-134a, R-404A, R-407C, and R-290. Zeotropic blends such as R-454B and R-407C provide distinct dew and bubble curves so your superheat and subcooling calculations stay accurate.
Does HvacGauge work completely offline in basements and rural areas?
Yes. Every P-T chart, superheat and subcooling formula, fault matrix, capacitor test, line-set calculator, and client equipment database runs 100% locally on your Android device without an account or cell signal.
How does HvacGauge handle zeotropic refrigerants like R-454B and R-407C?
Zeotropic blends experience temperature glide between vapor saturation (dew) and liquid saturation (bubble). HvacGauge exposes both dew and bubble curves and automatically pairs the proper curve with superheat and subcooling calculations, while displaying an A2L or A3 safety banner on every manifold screen.
What is included in the free plan versus HvacGauge Pro?
The free plan gives you full access to all 8 P-T charts, superheat/subcooling diagnostics, the fault matrix, capacitor testing, and line-set weigh-in tools, plus storage for up to 3 client units and 1 commissioning certificate PDF. HvacGauge Pro unlocks unlimited client units, unlimited diagnostic logs, and unlimited commissioning and warranty PDFs.
Can HvacGauge replace the manufacturer's OEM charging chart?
HvacGauge is a field calculator and documentation assistant designed to speed up diagnostics and reporting. Technicians should always verify critical readings against the equipment manufacturer's published P-T chart and follow EPA 608 safe refrigerant handling procedures.

Companion Web Tools & Guides

All Field Trades

Ready to Try HvacGauge on Android?

Install HvacGauge: HVAC Charge & P-T directly from Google Play. Built by Billin for offline speed and local-first privacy.